Spyder Studio for Windows 7, Windows 8.1, and Windows 10 Release Notes. Upgrade note: ============================ If upgrading from a previous version, we strongly recommend performing a backup of the system data using the backup feature of the Spyder Studio client software. Also, remove any previous versions of the product by using 'Add / Remove Programs' in the Windows control panel. Legend: ============================ [+] new feature [-] bug fixed or removed [*] bug fixed and improvement made [N] general note [K] known issue Stability Index: ============================= The stability index provides a benchmark over the level of quality involved in a specific release or beta version of software. Before installing any beta software versions, be sure to check the stability index. Why make Alpha / Beta software available to users: Christie products are defined and refined from customer feedback, and sharing pre-release software tightens the feedback loop, greatly increasing the user experience available in release versions. Stability Index Scale (1-5) =========================== 1: (Alpha) Released for testing of specific features. Software features may not be complete and may even contain severe issues or contain broken features or functionality. Users are strongly urged NOT to run this software in a production environment. 2: (Alpha) New features are considered to be complete or very close to completion. Little testing has been performed on the overall functionality of the build, and is not recommended for production use. 3: (Beta) Build has received a large amount of internal testing, and is considered to be in fair overall working condition. This build is recommended for expert-level Spyder users interested in previewing and testing new functionality and fixes available since the last release version, in a non-production environment. 4: (Release Candidate) Software considered to be production ready. Software builds in this state receives extensive testing internally, and is recommended for intermediate to expert users interested in providing feedback on the build. In cases where specific issues have been resolved since the previous release, Christie may recommend the use of this software in a production environment. Manuals and other documentation may not yet be complete at this stage. 5: (Release) Software is considered production grade, and the software package is being distributed as an official release. This software is recommended for production use, and new units purchased are shipped with the latest release version. Be sure to read any applicable release notes, if available, before updating software to be informed of any 'breaking changes' or other notes. What's new in the Spyder Studio Client Version 5.4.1 (06-15-2020) =================================================================================================== Spyder FPGA Date: CP 20200511 IC 20200513 OC 20200601 IP 20200103 OP 20191206 =================================================================================================== Stability Index: 5 (Release) =================================================================================================== 1. [+] Added new user interface control to reset stereoscopic input eye alignment 2. [+] Added Reset Stereo Signal (RSS) to external control protocol 3. [+] Added option for backup source switching to be immediate, bypassing time-consuming transitions that prolonged the time a failed source remains on screen 4. [+] Added property panel option to either keep only one panel open at a time (default) or allow multiple panel sections to be open at the same time. 5. [+] Increased maximum supported VI height in 12 bit mode to match 8-bit mode. Note that maximum supported input horizontal resolution decreases as VI grows above 4320 tall 6. [+] When creating a mix of stereoscopic and non-stereoscopic PixelSpaces in a new configuration, non-stereoscopic PixelSpaces no longer consume alternate eye pixels 7. [*] Modified behavior of the checkboxes on the 'View' menu to toggle open/close states on panels, similar to Vista Advanced 4.x behavior 8. [*] Changed user diagnostics monitoring startup to occur after the Spyder frame has completed startup to avoid reporting of invalid errors 9. [*] Added confirmation dialog when deleting a PixelSpace using the system patch 10. [*] Front panel UX improved in scenario where a popup message is present and the lock screen is enabled 11. [*] Scripting window now clears contents after applying a new configuration 12. [*] Improvements to adding stills and refreshing stills lists 13. [*] General improvements to 'Tools' --> 'Options' property panel 14. [*] Removed invalid warnings generated in User Diagnostics 15. [*] Reposition window checkbox in the layer crop properties area was hidden in some cases 16. [*] Improvements to image / thumbnail capture 17. [-] Fixed issue where recalling two absolute command keys could cause both scripts to appear in the PGM state 18. [-] Fixed issue where removing a layer from PGM could cause the layer to flicker in the multiviewer preview 19. [-] Fixed an "Exception has been thrown by the target of an invocation" error that would pop-up when running the hotsync operation 20. [-] Fixed issue with layer property panel test patterns overlapping with the Dynamic Help window 21. [-] EDID manager option to 'Add from Factory DP' was adding an HDMI default EDID 22. [-] Script cue property panel areas that were previously collapsed get expanded when selecting a new script cue 23. [-] SDI outputs were not properly loading SDI 10-bit values for bit depth after a configuration restore 24. [-] Fixed issue where output config property panel settings were not always saving while creating a new configuration 25. [-] Fixed a NullReference exception that could occur when working with the script grid control 26. [-] Fixed issue with System Layout panel not properly rendering all PixelSpaces in certain configurations 27. [-] Color picker control in command keys property panel wouldn't apply the entered value unless the user pressed the enter key within the control 28. [-] Clicking the Cancel button after selecting 'Add Multi Key' in the command key grid would still create a multi key 29. [-] In the Function keys grid, removing a page and selecting option to move to a different page could move keys to unexpected register locations on the specified page 30. [-] Fixed issue where custom test patterns on the front panel couldn't be removed 31. [-] Capturing layer thumbnail in PVW would capture the wrong thumbnail in some scenarios. 32. [-] Fixed issue where layer with bitmap border applied would change to a standard rectangular border when 'Size to Display Height' alignment is applied 33. [-] Connecting to a Spyder server while already connected to another Spyder server could cause the client application to crash 34. [-] Fixed issue where dragging a source or still to cue 1 could show an invalid drop location, requiring a drop to cue 2 and then moving the script element up to cue 1. What's new in the Spyder Studio Client Version 5.4.0 (01-14-2020) =================================================================================================== Spyder FPGA Date: CP 20190617 IC 20191110 OC 20200103 IP 20200113 OP 20200108 =================================================================================================== Stability Index: 5 (Release) =================================================================================================== 1. [+] Added support for test patterns on outputs in stereoscopic modes. 2. [+] X80 now supports PixelSpace spacing of 16 pixels (reduced from 64 pixels in previous releases). New configurations will use the new offset automatically. 3. [+] Added ability to optionally assign a password for connecting to Spyder. Can be reset/recovered from Admin page on front panel if needed. 4. [+] Added some additional counters and warnings to user diagnostics for improved system hardware troubleshooting. 5. [+] Updated signing certificate for Spyder Studio installer. 6. [+] Added support for Dexon Dimax-Pro router control. 7. [+] Added additional factory output formats to normalize the list for different refresh frequencies. 8. [*] Low latency mode for inputs is now off by default. Enable on a per-source basis by setting the UseAlternateInputSynchronization flag in advanced input configuration settings to 'off'. Useful for camera sources, but may affect smooth window motion. 9. [-] Source list wasn't being cleared after creating a new configuration with the option to clear sources and input configurations options selected. 10. [-] Fixed an issue in prior beta where layers in program may show an intermittent flicker. 11. [-] Fixed an issue where layer 1 in the multiviewer preview could flicker occasionally in some scenarios. 12. [-] Fixed issue with SDI outputs occasionally not initializing properly after a system boot. 13. [-] Fixed crash that occurred when opening the EDID manager when the client locale was in Deutsche. 14. [-] General fixes to support frame sequential stereoscopic video, introduced in previous beta. 15. [-] Fixed issue with bitmap border not clearing when applied to a still image in some cases. 16. [-] Option to 'Capture to Image' on system patch output context menu wasn't saving image correctly when in aux output mode. 17. [-] Fixed issue where cropping layers with bitmap borders applied weren't rendering properly. 18. [-] Fixed issue in prior beta build where program layers may re-appear on screen unexpectedly. 19. [-] Fixed issue with some script property panel values getting overwritten when switching selection between script elements. 20. [-] Misc fixes related to lower latency introduced in beta versions past the prior 5.3.2 release. What's new in the Spyder Studio Client Version 0.100.19319.2003 (11-15-2019) =================================================================================================== Spyder FPGA Date: CP 20190617 IC 20190806 OC 20190827 IP 20190811 OP 20190714 =================================================================================================== Stability Index: 3 (Beta) =================================================================================================== 1. [+] Added frame sequential stereoscopic support (100Hz and 120Hz) for inputs and outputs. 2. [+] Added layer lock support. Layers can be locked / unlocked from script or system patch window, preventing them from being accidentally bumped in the simulator. 3. [+] Added Request Active Sources (RAS) External API command. This command returns a list of sources currently in preview or program for tally indicator use. 4. [*] HDMI outputs now are held in reset longer while switching formats to prevent some display devices from locking to the wrong format or not locking intermittently. 5. [*] Minimum aspect ratio offset updated to -0.1940 to prevent invalid display of layers with extreme A/R offset values 6. [-] Fixed issue where the system would fail to initialize if the front panel display isn't physically working 7. [*] Clone options in keyframe panel are disabled on a layer in 2D (non-stereo) mode when placed on a stereoscopic PixelSpace. 8. [-] Fixed issue where deleting a PixelSpace in the system patch did not delete it's background image on the VI. What's new in the Spyder Studio Client Version 0.100.19254.0025 (09-13-2019) =================================================================================================== Spyder FPGA Date: CP 20190617 IC 20190806 OC 20190827 IP 20190811 OP 20190714 =================================================================================================== Stability Index: 3 (Beta) =================================================================================================== 1. [-] Fixed upscaling artifact appearing on layers noticeable with certain types of content 2. [+] Input-to-layer system latency modes are now managed automatically by X80 to ensure lowest possible latency for the current input and keyframe settings 3. [-] Fixed issues with border and shadow related to low latency modes introduced in prior beta 4. [-] Navigating command key and functio key pages using keyboard up/down arrow keys wasn't always working as expected 5. [*] Firmware update process updated to support certain firmware update operations no longer require a full power cycle 6. [-] Reduced the number of hotplug operations occurring on HDMI inputs at startup to resolve occasional connectivity issues with certain source devices 7. [-] PixelSpace name displayed in Spyder Studio multiviewer would not update when changed via the property panel 8. [-] Simulator in Spyder Studio wasn't rendering layer crop properly 9. [-] Fixed an error in the new configuration UI that could occur when multiple outputs were selected 10. [+] External control command Output Config Mode (OCM) now supports setting Aux mode 11. [-] Resolved an issue from the prior beta where stills on layers may not load properly the first time after a system restart 12. [-] The 'exit source configuration mode' link in the output property panel displayed when selecting an output in config mode was not working 13. [+] Reduced the amount of time spent processing when clicking the link to create a new source from the new source property panel 14. [-] Fixed an error that could occur in Spyder Studio when opening the User Diagnostics dialog 15. [-] Fixed an issue with command key buttons appearing cut-off in the command keys window What's new in the Spyder Studio Client Version 0.100.19219.2231 (08-08-2019) =================================================================================================== Spyder FPGA Date: CP 20190617 IC 20190802 OC 20190719 IP 20190802 OP 20190714 =================================================================================================== Stability Index: 2 (Alpha) =================================================================================================== 1. [N] This build has a low stability index and is considered to be a tech preview of SSO and lower system latency 2. [K] This build contains intermittent issues with still images and bitmap borders 3. [+] Added stereoscopic (SSO) feature support. Properly licensed systems now support passive (dual-input / dual-output) stereo 4. [+] Implemented changes in inputs and outputs to reduce system latency (experimental) 5. [+] In parallel X80 systems, each frame can now be configured with it's own configuration output 6. [*] Source config mode now uses the aux mode of the configuration output, removing use of a layer in PGM or the fallback of a lower resolution PVW layer. 7. [+] Added 'Select All' / 'Select None' link label buttons to the treatment property panel 8. [-] Fixed issue where layers could disappear in multiviewer preview when zoomed to certain sizes 9. [*] Updated alert viewer to include additional log messages that were previously not captured 10. [+] Updated firmware update process to use faster verification mechanism. Future firmware updates will be substantially faster as a result 11. [*] SDI output formats will now default color space to 709 or 2020, and will set the chroma to 4:2:2 12. [-] Fixed issue with fully cropped layers would leave a single pixel horizontal or vertical line on the VI 13. [-] Fixed issue where hardware information was not populating properly in the Spyder X80 web page 14. [-] Fixed issue where downloading logs from the Spyder website would fail and report an error in some cases 15. [-] Fixed issue preventing user diagnostics 'Data Connection' fields from being reset 16. [*] Modified wake on LAN (WOL) logic to more intelligently restart Spyder frames after firmware updates. What's new in the Spyder Studio Client Version 5.3.2.0 (07-31-2019) =================================================================================================== Spyder FPGA Date: CP 20190508 IC 20190722 OC 20190724 IP 20190724 OP 20190521 =================================================================================================== Stability Index: 5 (Release) =================================================================================================== 1. [-] Fixed issue with clone windows clipping two pixels from their right edges in some scenarios 2. [*] Improved hotplug performance for HDMI inputs 3. [-] Fixed issue with outputs not not properly reading EDIDs from connected DisplayPort displays What's new in the Spyder Studio Client Version 5.3.1.0 (07-23-2019) =================================================================================================== Spyder FPGA Date: CP 20190508 IC 20190721 OC 20190529 IP 20190523 OP 20190521 =================================================================================================== Stability Index: 5 (Release) =================================================================================================== 1. [-] Fixed an issue where inputs could flicker occasionally What's new in the Spyder Studio Client Version 5.3.0.0 (06-03-2019) =================================================================================================== Spyder FPGA Date: CP 20190508 IC 20190520 OC 20190529 IP 20190523 OP 20190521 =================================================================================================== Stability Index: 5 (Release) =================================================================================================== 1. [-] Fixed issue where still images loaded to layers may appear scrambled after a system boot if no sources were previously applied to the layer 2. [-] Numeric editor control in new configuration UI wouldn't show values below 0 for PixelSpace X/Y 3. [*] Right-clicking to copy/paste output properties in new configuration UI now includes x/y position properties 4. [+] Added support for MST output configuration within the new configuration UI 5. [+] Added new stretch mode options for bitmap borders on layers. Now allows for Fill, Uniform, and custom A/R (useful for logos or other aspect ratio sensitive bitmap borders). 6. [+] Added ellipse shape for bitmap borders and shadows. Combined with 'Uniform' stretch option, this now allows for real round circle shapes for the bitmap border. 7. [+] Enabled user diagnotics counters that detect board-to-board link problems within an X80 frame. These counters were added in a prior beta but disabled until now. 8. [+] New configuration UI now has adjustment handles for scaled mode output destination window rectangles. 9. [*] Now able to enter lower resolution values than 640x480 for output resolution. Useful for custom LED controller configurations. 10. [*] Removed SMTPE format option for loading standard resolutions on the output property panel. This will be re-introduced in a later build. 11. [*] Updated external control API document to add commands that were lost from the 4.x Vista Advanced software API document. What's new in the Spyder Studio Client Version 0.100.19137.1755 (05-17-2019) =================================================================================================== Spyder FPGA Date: CP 20190515 IC 20190514 OC 20190516 IP 20190509 OP 20190516 =================================================================================================== Stability Index: 3 (Beta) =================================================================================================== 1. [*] Changed frame ID display in new configuration UI to be zero indexed for consistency with the rest of the system. 2. [-] Fixed issue with PlayItems property panel not displaying machine control section. 3. [+] Added 'Select All' and 'Select None' link buttons to the Add New Treatment dialog. 4. [+] Added Aux function key to set source to an aux output 5. [*] Modified Aux output functionality introduced in prior beta to reference a source instead of an input ID. 6. [-] Backup source function key was missing sources in the sources drop down list. 7. [+] User diagnostics support for link diagnostics is now functional. What's new in the Spyder Studio Client Version 0.100.19122.2336 (05-05-2019) =================================================================================================== Spyder FPGA Date: CP 20190125 IC 20190426 OC 20190430 IP 20190502 OP 20190424 =================================================================================================== Stability Index: 2 (Alpha) =================================================================================================== 1. [-] Fixed issue with layer cropping causing image corruption in certain configurations 2. [-] Fixed issue with layers not removing from screen in some keyframe configurations What's new in the Spyder Studio Client Version 0.100.19121.2134 (05-01-2019) =================================================================================================== Spyder FPGA Date: CP 20190125 IC 20190426 OC 20190430 IP 20190429 OP 20190424 =================================================================================================== Stability Index: 2 (Alpha) =================================================================================================== 1. [-] Fixed issue with layers disappearing or appearing corrupted when set with certain keyframe configuration parameters 2. [-] Fixed an issue where attempting to load a SMTPE output format would result in a Spyder Studio crash due to a missing CDS.Smtpe.dll file. 3. [-] Fixed issue with output scaled mode not being configured correctly 4. [-] Fixed issue where native image capture would save an image shifted a couple pixels horizontally What's new in the Spyder Studio Client Version 0.100.19115.0118 (04-24-2019) =================================================================================================== Spyder FPGA Date: CP 20190125 IC 20190416 OC 20190423 IP 20190417 OP 20190419 =================================================================================================== Stability Index: 2 (Alpha) =================================================================================================== 1. [-] Multiviewer wasn't working if the output was set to a resolution of 4096x2160 2. [+] Inputs now support 7680x1080 resolution. Rules below: - Vertical input resolution decreases as horizontal resolution increases beyond 4096 pixels. When using a 7680 pixel wide input, it's max supported height is 1080. - VI height decreases as horizontal resolution increases beyond 4096 pixels. When using 7680 pixel wide inputs, the max VI height is 2160. 3. [*] EDID manager no longer requires explicit CEA/DID extension checkbox - extensions will be added automatically when necessary for the target format. 4. [+] EDID manager now supports generation of higher resolution preferred timings to support input resolutions above 4096x2160 5. [+] Input HDCP authentication status is now reported in user diagnostics 6. [-] Dragging and dropping sources into script window elements wasn't always applying properly 7. [*] Improved front panel message for certain scenarios where input hardware initialization fails 8. [+] Added API command for capturing full-frame input/output images 9. [+] Added support to system patch context menu to capture native resolution image files from inputs or outputs 10. [-] Snapping a layer to the bottom of a pixelspace using the layer alignment buttons in the simulator was a pixel off vertically in some configurations 11. [+] Added Scaled Aux support to outputs. Set scaled aux mode and associated input from output properties panel. 12. [+] Output config panel now allows selection of SMTPE formats. 13. [*] Removed A/B level setting on input config property panel for SDI, as displaying this is unavailable 14. [*] Thumbnail capture for a source is now disabled when HDCP is enabled 15. [-] Fixed issue where outputs may not load correctly at startup when blending is enabled 16. [+] Added Display Port output support for Multi-Stream Transport (MST) output connections. Configuration handles available on output property panel. 17. [*] Input configuration raster handles now allow for finer adjustment 18. [*] Updated context menu items in simulator to show associated keyboard shortcut keys. 19. [-] Fixed issue with function key and command key grids where bottom row of buttons would get physically cut off in UI 20. [+] Multiple selected function keys can now be CTRL+dragged in the function key grid to copy all selected items 21. [*] User diagnostics window now automatically refreshes certain data as it's made available by the server. Clicking refresh will still refresh all data manually. 22. [*] Replaced exclamation icons with information icons on output properties menu where information about available states are displayed 23. [*] Added user diagnostics counters for board-to-board checksum error reporting. This is not yet functional - a firmware update in a future build will begin populating these counters 24. [+] Added frimware and CPLD version information to user diagnostics 25. [*] Added clock cleaner diagnostic information to user diagnostics for outputs 26. [-] Fixed an issue where IP / version information would not correctly load on the X80 front panel occasionally when booting 27. [-] Fixed an issue with X/Y positions not applying correctly to outputs in scaled mode when the output was rotated 90 or 270 degrees 28. [-] Fixed issue with HDCP license option status not being displayed in the license manager UI 29. [-] Fixed issue with multiviewer on slave frames not showing the source name properly in UI 30. [-] Fixed issue where Spyder Studio could crash when changing pixelspace names in the new configuration UI 31. [*] Now blocking changes to an output from the output property panel when that output is the source config output and the system is currently configuring a source. 32. [*] When sending output configuration related API commands, config mode will now exit automatically if the output is the source config output and the system is currently configuring a source. 33. [-] Fixed Spyder Studio crash which would occur when adjusting the background color of an output from the advanced section of the output properties panel 34. [-] Fixed mirror mode of layer clones not working on slave frames 35. [*] Improved application fatal error dialog to include a details button to help capture stack trace information when a UI error occurs. 36. [-] Layers on slave frames were not clearing when restarting the main frame 37. [*] Output blending application modified internally - blend loading may be generally faster. 38. [-] Fixed issue in function key properties panel where function keys that accepted layer or device counts might need to be clicked twice to get the layer list to load properly 39. [*] Input gamma control now available in input configuration property panel 40. [*] New configurations now show frame IDs starting at 0 instead of 1 to be consistent with frame numbering elsewhere in the system 41. [*] Added support in X80 hardware for the 'Lock front panel' startup option under 'Server' --> 'Frame Configuration' in Spyder Studio. 42. [+] System internal speed increased. Maximum VI size increased to 78.4 million pixels in 8-bit mode What's new in the Spyder Studio Client Version 0.101.19114.2023 (04-24-2019) =================================================================================================== Spyder FPGA Date: CP 20190125 IC 20190416 OC 20190419 IP 20190418 OP 20190226 =================================================================================================== Stability Index: 4 (Release Candidate) =================================================================================================== 1. [-] Fixed rounding issue in brightness, contrast, saturation, and hue adjustments that could cause input artifacts 2. [-]Fixed issue wit interlaced inputs not being detected and configured properly after system starts up, requiring additional autosync 3. [-] Fixed issue with keyed sources on layers not being fully opaque, allowing lower layers to partially show through 4. [-] Fixed issue with layer clones showing corrupted data along top line of video in some scenarios 5. [-] Fixes issue with clones causing bottom/right pixels to be transparent in some size/position combinations What's new in the Spyder Studio Client Version 0.101.19113.2015 (04-23-2019) =================================================================================================== Spyder FPGA Date: CP 20190125 IC 20190125 OC 20190419 IP 20190222 OP 20190226 =================================================================================================== Stability Index: 4 (Release Candidate) =================================================================================================== 1. [*] Improved Display Port link training on outputs to support more display devices, including Christie Link. What's new in the Spyder Studio Client Version 0.101.1960.0135 (03-01-2019) =================================================================================================== Spyder FPGA Date: CP 20190125 IC 20190125 OC 20190123 IP 20190222 OP 20190226 =================================================================================================== Stability Index: 4 (Release Candidate) =================================================================================================== 1. [-] Fixed an issue where outputs can show green 'sparkles' on outputs on certain X80 systems in some rare cases. What's new in the Spyder Studio Client Version 5.2.2 (03-01-2019) =================================================================================================== Spyder FPGA Date: CP 20190125 IC 20190125 OC 20190123 IP 20190222 OP 20180910 =================================================================================================== Stability Index: 5 (Release) =================================================================================================== 1. [-] Fixed an issue causing window clone images to possibly appear visually degraded from the original window. What's new in the Spyder Studio Client Version 5.2.1 (02-21-2019) =================================================================================================== Spyder FPGA Date: CP 20190125 IC 20190125 OC 20190123 IP 20180913 OP 20180910 =================================================================================================== Stability Index: 5 (Release) =================================================================================================== 1. [-] Fixed issue layers with test patterns loaded and then mixed off could become unavailable until the image was cleared using the system patch. 2. [-] Fixed isue with mixers not transitioning at the same time. 3. [-] Fixed issue where a network error dialog could appear on the front panel and remain even after recovering from lost network connectivity. 4. [-] Layer transparency offset wasn't being displayed correctly in preview when recalling command keys in some scenarios. 5. [*] Firmware update verification process improved to retry reading of blocks when upon rare read failure scenarios. What's new in the Spyder Studio Client Version 5.2.0 (01-31-2019) =================================================================================================== Spyder FPGA Date: CP 20190125 IC 20190125 OC 20190123 IP 20180913 OP 20180910 =================================================================================================== Stability Index: 5 (Release) =================================================================================================== 1. [-] Fixed Mixers to recall correctly each time 2. [*] Improved copy/cut/paste features on command key and function key pages 3. [K] Stills as mixers have a longer load time than sources and may cause PGM flicker if transitioned before the load is complete What's new in the Spyder Studio Client Version 0.100.1928.2119 (01-29-2019) =================================================================================================== Spyder FPGA Date: CP 20190125 IC 20190125 OC 20190123 IP 20180913 OP 20180910 =================================================================================================== Stability Index: 4 (Release Candidate) =================================================================================================== 1. [-] Fixed device features to work with 12 mixers on a single unit 2. [-] Fixed scaled output issue on slave X80 frames 3. [-] Fixed multiviewer on slave frames to work with any configuration 4. [-] Fixed User diagnostic's file to be included so the software doesn't crash when opening 5. [-] Fixed EDID manager from crashing while adding a new EDID in virtual mode 6. [-] Fixed configure source to work on slave frame in a parallel system 7. [-] Fixed OCF API command to update advanced properties 8. [+] Added reduced blanking options to the OCF API command 9. [-] Fixed misspelled word in mixer element property section 10. [-] Improved mixer switching with still images 11. [-] Fixed the spyder studio web page 12. [-] Improved HDCP 1.4 reliability on HDMI inputs 13. [K] Mix thru black sometimes won't recall source layers after still image was in use What's new in the Spyder Studio Client Version 0.100.1916.1947 (01-16-2019) =================================================================================================== Spyder FPGA Date: CP 20181113 IC 20190111 OC 20190110 IP 20180913 OP 20180910 =================================================================================================== Stability Index: 3 (Beta) =================================================================================================== 1. [K] Still images as mixers will freeze source element if in a cue script 2. [*] Fixed inputs to sync correctly on ports below the first on each card (bug introduced in .2314 beta) What's new in the Spyder Studio Client Version 0.100.1911.2314 (01-14-2019) =================================================================================================== Spyder FPGA Date: CP 20181113 IC 20190111 OC 20190110 IP 20180913 OP 20180910 =================================================================================================== Stability Index: 3 (Beta) =================================================================================================== 1. [K] The web page in this build is disabled and will be returned in a future build 2. [+] Added user diagnostics UI and popup for detected warnings 3. [+] Added HDCP 2.2 and 1.4 support for HDMI inputs. 4. [N] Enabling HDCP support requires a new license to be applied to each X80 frame (start at 'help --> License Manager') 5. [+] Returned the checkbox for 'Reduce Blanking' to load output formats 6. [-] Fixed an issue causing output configuration video timings to not load correctly occasionally 7. [-] Fixed an issue where capturing a source thumbnail could cause the X80 frame to hang. 8. [+] Scripting engine now supports stills in mixer elements 9. [-] Fixed issue where connector type drop down may appear blank for input, source, and output property panels 10. [-] Outside softness on layers looked different between PVW and PGM 11. [-] Fixed exception that could occur when loading Function key files 12. [-] Fixed issue with renaming still file from the stills property panel when connected to a server, causing file names to get out of sync with registers 13. [-] HDMI outputs would occasionally not work on power up or when dicsonnecting/re-connecting cables from the output 14. [+] Updated Spyder Studio user's guide with information on parallel configurations 15. [-] Absolute Y position editor in layer properties panel was not properly translating values to relative coordinates 16. [+] Added new Multiviewer control commands to external control protocol 17. [-] Configure source wasn't working when config output is set to UHD or 4K resolution 18. [-] Output Configuration Format (OCF) - Vesa timing calculation wasn't setting correct values for interlaced formats 19. [*] Aspect ratio offset precision increased to 4 decimal places to resolve rounding issues that could occur in some configurations 20. [-] Fixed issue with multiviewer configuration UI not showing PVW PixelSpaces after adding a PixelSpace until a preset is re-created 21. [-] Selecting configure source would sometimes show the wrong source 22. [*] Multiple mixers transitioning at the same time wouldn't always start tranisitioning at the same time. Transition starts are now synchronized for mixers where content is ready. 23. [-] Add Freeze device function keys show invalid device selection options in some scenarios 24. [-] Add Freeze device function key property panel was scrolling to the top of the list each time selection changed 25. [-] Custom multiviewer PGM would appear distorted on screen ith certain horizontal positional values 26. [-] Scaled mode was not working on slave frames 27. [+] Added ability to read EDID on outputs and select output configuration format based on reported available EDID timings 28. [*] Changed board programming behavior to not reprogram processor cards when one or more input processor cards are not detected at startup 29. [-] After power cycling the X80 frame, occasionally outputs would not switch to multiviewer mode propertly 30. [-] Fixed issue where Spyder Studio client could lock up in certain rare configurations What's new in the Spyder Studio Client Version 0.100.18347.1517 (12-13-2018) =================================================================================================== Spyder FPGA Date: CP 20180903 IC 20181008 OC 20181022 IP 20180913 OP 20180910 =================================================================================================== Stability Index: 3 (Beta) =================================================================================================== 1. [-] Fixed issue where HDMI output info frame would not report it's VIC as 0 when set to a custom resolution. What's new in the Spyder Studio Client Version 0.100.18297.1253 (10-24-2018) =================================================================================================== Spyder FPGA Date: CP 20180903 IC 20181008 OC 20181022 IP 20180913 OP 20180910 =================================================================================================== Stability Index: 3 (Beta) =================================================================================================== 1. [+] Improved parallel configuration for most systems to see correct hardware on boot up. 2. [K] Issue with dropping a source on the slave pixelspace [parallel only] (work around by right click to add a layer) 3. [-] Fixed Read EDID from display device to read the correct port and auto name from the output 4. [-] Fixed applying an EDID to slave frames 5. [-] Fixed parallel layer positioning to align to the correct pixelspace 0x0 positions 6. [-] Improved source auto syncing accuracy to color and timings 7. [-] Fixed source mon to automatically come back after a restart 8. [-] Fixed OCF API command to update advanced properties 9. [+] OCM to include Multiviewer 10. [+] Allow user to modify frame AOR to be smaller than the maximum size 11. [+] Added information on server > connection manager to see what version software the client is currently running 12. [-] Removed basic presets, backgrounds, and layer control from the UDP properties panel 13. [+] Updated Dynamic help menu for software selections 14. [-] Fixed layers from jumping after a transition with a mix background cue 15. [+] Added thumbnail support for parallel frames 16. [-] Fixed video timings in output properties to accept changes without jumping back to 0 17. [-] Fixed updating frames to update properly while in parallel 18. [-] Fixed layer movement to be in sync per frame basis 19. [+] Added support for saving CVT 1.1 EDID files in CVT 1.2 format 20. [-] Fixed still images to recall properly after a restart 21. [+] Added options for users to import EDID files that will be unmodified once added 22. [+] Added 1080p 60hz to the factory format list 23. [-] Fixed Multiviewer clones to not break when partially off of the left edge of the pixelsapce 24. [+] Added support for shutting down slave frames if they overheat 25. [N] Improved output resolution timings in OC firmware 26. [N] Improved input syncing issues in IC firmware What's new in the Spyder Studio Client Version 0.100.18283.1912 (10-10-2018) =================================================================================================== Spyder FPGA Date: CP 20180903 IC 20180926 OC 20180825 IP 20180913 OP 20180910 =================================================================================================== Stability Index: 4 (Release Candidate) =================================================================================================== 1. [+] Added GrassValley Series 7000 router protocol 2. [+] Added ProBel SW-P-08 router protocol What's new in the Spyder Studio Client Version 5.1.0 (09-26-2018) =================================================================================================== Spyder FPGA Date: CP 20180903 IC 20180926 OC 20180825 IP 20180913 OP 20180910 =================================================================================================== Stability Index: 5 (Release) =================================================================================================== 1. [K] PVW on MV border and shadow limitation on output - will be correct on the simulator PVW and in PGM 2. [-] Fixed 'is connected' indicator on inputs 3. [-] Fixed applying configuration output settings to stay once applied 4. [-] Fixed adjacent output settings on outputs to update properly 5. [-] Fixed EDID's applying to all four ports on the input card to just the selected ports What's new in the Spyder Studio Client Version 0.100.18264.1502 (09-24-2018) =================================================================================================== Spyder FPGA Date: CP 20180903 IC 20180920 OC 20180825 IP 20180913 OP 20180910 =================================================================================================== Stability Index: 4 (Release Candidate) =================================================================================================== 1. [-] Improved display port inputs syncing 2. [-] Improved EDID import function to read EDID properly What's new in the Spyder Studio Client Version 0.100.18263.1345 (09-20-2018) =================================================================================================== Spyder FPGA Date: CP 20180903 IC 20180914 OC 20180825 IP 20180913 OP 20180910 =================================================================================================== Stability Index: 3 (Beta) =================================================================================================== 1. [-] Fixed RRD command for still images 2. [-] Fixed inputs to correctly switch designated input config 3. [-] Fixed Rotated outputs 4. [-] Fixed placing an input on the simulator issue where sometimes it would show the wrong source. 5. [K] HDMI EDID issue without CEA extention enabled 6. [-] Fixed noise at the bottom on the VI on outputs when full canvas is in use 7. [-] Fixed C - F temperature conversion to correct F value 8. [-] Fixed some cloning noise issues on certain left and bottom positions 9. [-] Fixed border from becoming thicker when zoom is enabled 10. [-] Fixed router to not repatch 1-1 after applying a new config from load current 11. [-] Fixed USB false message on the front panel on some units 12. [-] Fixed fatal error when deleting a used EDID in the EDID manager 13. [-] Improved Parallel system patch pixelspaces 14. [-] Fixed GUI to not show old outputs in configuration manager after building a parallel config 15. [-] Improved layer movement on the outputs while moving in a cluster 16. [-] Fixed Multiviewer function key to recall when it is a part of a script 17. [-] Fixed bootup issue with some control processors 18. [K] Potential AMD input card won't sync 19. [K] Multiviewer might not switch back to Multiviewer if changed to normal mode 20. [-] Improved EDID writing to inputs properly What's new in the Spyder Studio Client Version 0.100.18244.1757 (09-01-2018) =================================================================================================== Spyder FPGA Date: CP 20180806 IC 20180827 OC 20180825 IP 20180828 OP 20180831 =================================================================================================== Stability Index: 3 (Beta) =================================================================================================== 1. [-] An SDI router added from the new config UI would patch odd connectors only when connected to X80 hardware. 2. [-] Input number wasn't auto-incrementing in the new source property panel if Multiviewer was unavailable. 3. [-] Autosync wasn't updating the chroma value 4. [-] Fixed some clone window clipping edge-cases that could cause scrambled layers and flickering 5. [-] Crop feature was not working with 4K sources in some scenarios 6. [-] Color key wasn't being applied when in source config mode 7. [-] Added better bounds checking to scaled output source and destination rectangles 8. [+] Now allowing a height of 6480 when in 8-bit VI mode 9. [-] When switching Spyder Studio connection between two servers, the input configuration panel was writing the last selected layer's config to that layer ID on the newly connected server. 10. [-] EDID manager was showing duplicate entries in the list after applying EDIDs 11. [-] Fixed error with EDID manager that would occur after applying a custom EDID and then deleting the EDID from the list 12. [*] Improved update process for multiple frames in parallel expansion. 13. [-] Fixed issue where old dialogs on the front panel would re-appear only when screen saver was active. 14. [-] Fixed issue with new configuration UI resetting an existing routers patch to unity if other routers were added/modified during a new config. What's new in the Spyder Studio Client Version 0.100.18228.1748 (08-18-2018) =================================================================================================== Spyder FPGA Date: CP 20180806 IC 20180810 OC 20180816 IP 20180816 OP 20180518 =================================================================================================== Stability Index: 3 (Beta) =================================================================================================== 1. [-] Fixed scenario where preview layers in multiviewer may freeze if video inputs momentarily lose connection 2. [-] Fixed issue where the incorrect source could appear in multiviewer preview in some cases. 3. [-] Fixed noise appearing on scaled outputs in some configurations. 4. [+] Added ScaledSourceWindow and ScaledDestWindow handles for scaled mode outputs in the advanced section of the output property panel 5. [+] Added support for loading 12-bit still image files into background and layers. Actual file formats are typically 16-bit, and the server will convert to 8 or 12 bit based on VI bit-depth. 6. [+] Added support for parallel expansion of X80 frames. Requires PCIe cabling between control cards of frames. 7. [+] Added 'toggle' action to layer and device freeze function keys 8. [+] Added 'SwitchToPrimary' and 'Toggle' actions to backup source function keys 9. [+] Added layer cloning support. 10. [N] Layer clones do not support negative offset or some overlapping offset values in this build. This will be corrected in the next beta. 11. [-] Fixed issue where selecting an input in the multiviewer UI editor, then scrolling, then selecting a new input would not de-select the previously selected input. 12. [-] Resolved layer flickering / distortion that could occur when layers were cropped to specific values. Typically seen as a flicker while transitioning keyframes with different crop values. 13. [-] Fixed issue with server not restarting properly from the front panel occasionally. 14. [-] Fixed intermittent issues entering source config mode which could result in no layer appearing, layer flickering, or showing incorrect input. 15. [-] Slave layer selected item in the script element properties panel would lose visible selection state (highlight) when adjusting override options. 16. [-] Fixed issue where multiviewer output could flicker when no input was connected 17. [*] Renamed ReducedLatencyMode to UseAlternateOutputSynchronization, as ReducedLatencyMode wasn't really an accurate description of this field. As with the prior betas, leave this option defaulted until a future build. 18. [-] Fixed issue where sometimes outputs may not load normally after a full power cycle of the X80, requiring the user to modify a property on the output panel to force the config to be reloaded. 19. [+] Improved UDP protocol tester custom command by making error messages returned from the server more descriptive, and allowing success responses with no additional data to be hidden with a "Don't show this again" option. 20. [-] External Control - Transition Layer (TRN) wasn't working in some cases 21. [-] External Control - Request Script CueData Count (RSCC) command was always returning the script cue count + 1 22. [-] External Control - Request Register Data (RRD) would return the incorrect script count (+1) for command keys 23. [-] External Control - Freeze Output (OFZ) now works with X80 hardware. 24. [-] External Control - Output Configure Rotation (OCR) now works with X80 hardware. 25. [+] External Control - Treatment Learn (KTL) now supports duration, transparency, and size attributes. 26. [-] External Control - Shadow Adjust (KSH) was not correctly setting the shadow enable flag. 27. [-] Fixed issue where expanding test pattern section of output config panel could lock up Spyder Studio by getting stuck turning vertical scrolling on and off. 28. [-] Fixed an issue where HDMI and SDI inputs were not showing the 'Is Connected' indicator occasionally. 29. [-] Fixed issue with hardware console and Studio's transition controller that would cause PVW/PGM layer state for mixers to get confused and keep both layers in PVW bus 30. [-] In configurations where no PVW pixelspace exists, recalling the PVW cue of a command key would cause associated layers to mix onto PGM 31. [*] Modified X80 initialization to allow the server to startup and function normally in scenarios where the front panel is damaged or otherwise not connected to the system. 32. [*] Modified front panel to make transient error messages (typically network related) to clear automatically if the fault clears. 33. [-] Fixed issue where clicking the 'Transparency' checkbox on the treatments panel wouldn't update the treatment. As a workaround users had to then toggle some other option in the panel to commit changes. 34. [-] Fixed 'Add from Screens' option on command key grid, which should add from both PVW and PGM but was adding only from PGM. What's new in the Spyder Studio Client Version 0.100.18213.1213 (08-02-2018) =================================================================================================== Spyder FPGA Date: CP 20180406 IC 20180510 OC 20180716 IP 20180725 OP 20180518 =================================================================================================== Stability Index: 4 (Release Candidate) =================================================================================================== 1. [-] Added fix for a very small number of X80 embedded computers found to be entering sleep mode after running for a period of time. What's new in the Spyder Studio Client Version 0.100.18212.0847 (07-31-2018) =================================================================================================== Spyder FPGA Date: CP 20180406 IC 20180510 OC 20180716 IP 20180725 OP 20180518 =================================================================================================== Stability Index: 4 (Release Candidate) =================================================================================================== 1. [-] Fixed issue with layers appearing shifted to the right or shuddering horizontally in rare cases on some X80 systems. What's new in the Spyder Studio Client Version 5.0.3.2 (07-17-2018) =================================================================================================== Spyder FPGA Date: CP 20180406 IC 20180510 OC 20180716 IP 20180702 OP 20180518 =================================================================================================== Stability Index: 5 (Release) =================================================================================================== 1. [-] Fixed incorrect timings for UHD@50Hz 2. [-] Fixed issue with SDI outputs not displaying frames in sync with eachother. 3. [+] Added support for showing frame temperature on front panel in Fahrenheit (Server -> Frame Configuration) 4. [*] Replaced large color pickers in property panels with condensed color picker controls for better user experience 5. [-] Removed an errant dialog that could appear on the front panel with the message "Error setting IP address. Please set to an available IP address." 6. [-] 12-Bit VI wasn't allowing 4320 pixel tall configurations (dual UHD displays) 7. [-] Fixed issue with output timing taking several minutes to lock in when initializing or switching resolutions in some scenarios 8. [-] Fixed issue where a still image with an odd numbered pixel width may not load properly into a layer 9. [-] Fixed issue where the 'Factory' format radiobox on the output properties panel would be unavailable when certain custom format values were entered 10. [-] The source section of the layer properties panel wasn't being disabled when a still was loaded into a layer 11. [-] Fixed input autosync issue where SDI input metadata for Limited/Full Range was not always being interpreted correctly 12. [K] Using a recently added mode on the outputs called 'ReducedLatencyMode' may cause outputs to not initialize consistently after power cycling. We recommend leaving this off until a future release. What's new in the Spyder Studio Client Version 5.0.2.2 (07-09-2018) =================================================================================================== Spyder FPGA Date: CP 20180406 IC 20180510 OC 20180702 IP 20180702 OP 20180518 =================================================================================================== Stability Index: 5 (Release) =================================================================================================== 1. [-] Fixed issue where layers could disappear from the VI for a single frame occasionally 2. [-] Dropping a keyframe or treatment onto an element could add the keyframe to the wrong cue depending on where it was dropped. 3. [-] Fixed issue where bitmap border/shadow shape could render incorrectly when H and V offset are set to 255. 4. [-] A bug introduced in the last beta caused preview PixelSpaces to not be displayed in the simulator in view stacks other than the ALL PGM view 5. [-] Fixed an issue where the front panel wouldn't display correctly due to a window Z-order issue on the X80 computer video outputs 6. [-] Fixed issue in router patch UI where the physical output sorting could get out of order by default, requiring a user to click the column header to force sorting. 7. [-] Loading a layer to PVW then transitioning the layer to PGM would cause both PVW and PGM layers to get reset to PixelSpace ID 0 8. [-] EDID manager was not saving frame rate correctly for DID or CEA extension in some cases 9. [-] Multiviewer PVW would appear horizontally offset from PGM in some scenarios. 10. [-] All outputs on an output card were reloading their configuration, causing a brief flash, when entering or exiting multiviewer mode. What's new in the Spyder Studio Client Version 0.100.18176.1833 (06-25-2018) =================================================================================================== Spyder FPGA Date: CP 20180406 IC 20180510 OC 20180615 IP 20180129 OP 20180518 =================================================================================================== Stability Index: 4 (Release Candidate) =================================================================================================== 1. [-] Fixed issue with UHD outputs rotated 180 degrees where background image and layers show tearing 2. [-] Fixed issue with 4K@60Hz 4:2:0 inputs not working 3. [-] Fixed issue with test patterns not loading on rotated outputs 4. [-] Fixed issue where EDID read from display device was not working properly 5. [-] Fixed issue where sizing of layer to pixelspace width would cause the layer to be oversized by 1 pixel 6. [-] Fixed issue where SLD API command would report success but fail to load a still to a layer 7. [-] Fixed issue where background images may not load properly into multiviewer after build a new configuration 8. [+] Bit depth now being detected during autosync of input 9. [-] Fixed issue where PVW and PGM pixelspaces weren't lining up perfectly in the multiviewer 10. [-] Fixed issue where PVW pixelspaces in system patch weren't appearing directly below their associated PGM pixelspace 11. [-] Fixed issue where custom output resolutions were loading factory formats instead, preventing reduced blanking timings from being generated 12. [-] 'Cue length' property panel setting was missing for both mixer and input array elements 13. [-] Days of the week selection buttons were missing from the cue data property panel when 'TimeOfDay' cue trigger type was selected 14. [+] Implemented SDI level A/B 15. [*] Fans no longer spin up to be as loud as in previous versions upon start of server software 16. [*] Hiding SDI level controls in input configuration panel when input type is not set to SDI 17. [+] Added router control support for Christie Terra 18. [*] Removed sync type field from input configuration panel - it is no longer required. 19. [+] Renamed 'UserAlternateOutputSynchronization' flag in output config to ReducedLatencyMode. This mode is now available in X80 hardware What's new in the Spyder Studio Client Version 0.100.18136.1100 (05-17-2018) =================================================================================================== Spyder FPGA Date: CP 20180406 IC 20180510 OC 20180423 IP 20180129 OP 20180131 =================================================================================================== Stability Index: 4 (Release Candidate) =================================================================================================== 1. [-] Fixed output blending controls to update when user makes changes 2. [-] Fixed autosync "is connected" UI false warning 3. [-] Fixed Still image thumbnail folder recovery 4. [-] Fixed configuration manager to be quicker when configuring outputs 5. [-] Fixed command key recall crash 6. [-] Fixed software crashing intermittently 7. [-] Fixed "use back up" still image option 8. [-] Fixed MV overlay PGM and input swapping issue 9. [-] Fixed interlaced input reporting on auto sync to report correctly 10. [-] Fixed thumbnail capture on sources 11. [+] Added "isconnected" feature for input configuration 12. [+] Added "back up and restore" feature on front panel using USB drive 13. [+] Added "power options" feature on front panel 14. [+] Added HDMI 4.2.0 support on inputs 15. [+] Added chroma options to EDID manager 16. [+] Added backend support for quicker output resolution changes 17. [+] Added color range full and limited options on inputs and outputs 18. [+] Added auto sync to properly read the input signal coming in 19. [K] Restore from USB drive needs to manually have the software restarted (can be done via front panel) 20. [K] Fill source doesn't show the cut in PVW What's new in the Spyder Studio Client Version 0.100.18121.1548 (05-02-2018) =================================================================================================== Spyder FPGA Date: CP 20180406 IC 20180324 OC 20180423 IP 20180129 OP 20180131 =================================================================================================== Stability Index: 3 (Beta) =================================================================================================== 1. [-] Fixed router salvo max to work over 100 2. [-] Fixed Test patterns to save and auto refresh to still list when user chooses 3. [-] Fixed sync and rebuilding on still list to be more robust 4. [-] Fixed still image scaling on still images that are 256x144 or below in size 5. [-] Improved file transfer warnings and errors when trying to backup or restore configuration files 6. [-] Fixed "custom" output timing to update when changes are made 7. [-] Fixed getsdrawingdataupdate error in alert viewer 8. [-] Fixed incorrect routing for 4k routers 9. [+] Added PVW properties to redirect to PGM properties 10. [+] Added Keyframe layer transparency option 11. [+] Added SDI option level A/B to outputs 12. [+] Added autoblend adjacent output enhancement 13. [+] Added HDR control (this is only fully implemented for SDI in this build) 14. [+] Added absolute layer coordinates 15. [N] If back revved to previous version, PVW space will be removed - do file > new - load current - apply and it will come back. 16. [K] Software blending controls not responding to changes - won't disable or enable on outputs What's new in the Spyder Studio Client Version 0.100.18109.0919 (04-19-2018) =================================================================================================== Spyder FPGA Date: CP 20180406 IC 20180324 OC 20180415 IP 20180129 OP 20180131 =================================================================================================== Stability Index: 4 (Release Candidate) =================================================================================================== 1. [-] Improved IP address on front panel to restart the system when the address is changed by user 2. [-] Fixed copy and paste multiple function keys to paste correct ID's 3. [-] Fixed selecting multiple command keys and deleting them at the same time to delete all selected not just one 4. [-] Improved sync files and rebuild files in still list 5. [-] Fixed loading a test pattern to a pixel space to load across the pixel space not in just the output 6. [-] Fixed SDI input auto sync issue 7. [+] Support for 12-bit RGB and 10/12-bit YCbCr 4:2:2 outputs (OC firmware change) 8. [+] Added BT 2020 Gamma on outputs 9. [+] Added Layer transparency function in key frames 10. [K] Issues with backing up or restoring a config file and working with still images What's new in the Spyder Studio Client Version 5.0.1 (04-16-2018) =================================================================================================== Spyder FPGA Date: CP 20180406 IC 20180324 OC 20180405 IP 20180129 OP 20180131 =================================================================================================== Stability Index: 5 (Release) =================================================================================================== 1. [-] Improve scaling source config on Multiviewer 2. [-] Fixed static IP address to persist a crossed updates What's new in the Spyder Studio Client Version 0.100.18100.1359 (04-10-2018) =================================================================================================== Spyder FPGA Date: CP 20180406 IC 20180324 OC 20180405 IP 20180129 OP 20180131 =================================================================================================== Stability Index: 4 (Release Candidate) =================================================================================================== 1. [-] Fixed changing command keys between absolute and relative to update changes and not revert back after clicking away 2. [-] Fixed saving Multiviewer preset keys to save in backup file and "save function key" file's, and to persist across updates 3. [-] Fixed pixelspace still images to align correctly depending on where the pixelsapce H and V start begin. 4. [-] Fixed scripting keyframe warning from removing previous keyframe changes within the script 5. [-] Improved Inconsistent QFT error that causes system to occasionally lock up client and server communication 6. [-] Removed DNS server option on the front panel to avoid confusion while setting static IP addresses 7. [-} Improved Hardware communication reliability that would cause layer movement lockups 8. [-] Fixed output property slowness when you have multiple Multiviewer function keys 9. [+] Added SDI output factory format 2160p @50hz 10. [+] Added multiple of 8 warning to EDID manager for VESA timings in the UI What's new in the Spyder Studio Client Version 0.100.18096.1334 (no build posted) (04-06-2018) =================================================================================================== Spyder FPGA Date: CP 20180116 IC 20180324 OC 20180320 IP 20180129 OP 20180131 =================================================================================================== Stability Index: 4 (Release Candidate) =================================================================================================== 1. [-] Fixed stack horizontal and stack vertical from being backwards 2. [-] Fixed function keys from locking up software when second page is added with Multiviewer preset recalls 3. [-] Fixed function keys from deleting first page keys when second page keys are created 4. [-] Fixed shadows in the simulator window to follow what is shown on the output 5. [-] Fixed copy and paste multiple command keys to paste more than one 6. [-] Fixed option to select multiple command keys and delete multiple at the same time 7. [+] Enhanced "preview only scripting mode" to indicate user when software is in that mode What's new in the Spyder Studio Client Version 0.100.18092.1318 (no build posted) (04-02-2018) =================================================================================================== Spyder FPGA Date: CP 20180116 IC 20180324 OC 20180320 IP 20180129 OP 20180131 =================================================================================================== Stability Index: 4 (Release Candidate) =================================================================================================== 1. [-] Fixed function key re-learn option for Multiviewer presets 2. [-] Fixed test patterns to clear on layers 3. [-] Fixed API command KSH 4. [-] Fixed Multiviewer presets to save when applying a new config when data isn't cleared 5. [-] Fixed firewall blocking rule from blocking the montage controller from connecting to spyder studio 6. [-] Fixed fatal error when unchecking the CEA extension in the EDID manager 7. [-] Fixed source mon preset key to load correctly after first applying a new configuration 8. [+] Enhanced test pattern generator 9. [+] Changed shadow properties to H/V offset 10. [+] Enhance TX output mode to default to HDMI 11. [+] Updated server to use .net 4.7.1 for spyder studio - .net 4.7.1 is now required on PC's running spyder studio 12. [+] Enhance spyder studio alignment options on the simulator window 13. [K] Creating a second page with Multiviewer presets locks up software What's new in the Spyder Studio Client Version 5.0.0.3 (03-27-2018) =================================================================================================== Spyder FPGA Date: CP 20180116 IC 20180324 OC 20180320 IP 20180129 OP 20180131 =================================================================================================== Stability Index: 5 (Release) =================================================================================================== 1. [K] Stereoscopic configuration not yet implemented - future release 2. [K] Parallel (multiple X80's connected) not yet implemented - future release 3. [K] Input thumbnail capture does not capture all input images properly 4. [K] Limitation for boarders and shadows on large still images is not in place to prevent user from using a boarder to large for the size of the layer 5. [K] Inconsistent QFT error causes system to occasionally lock up client and server communication 6. [K] Using the "mix background" function key while layers are transitioning will cause layers to jump into place after the background mix is complete 7. [K] Can't clear test pattern with clear function when it is in a layer - have to drag and drop source or still into layer to clear 8. [K] Creating a source using an upstream router may show "invalid" in the source list on the sources until one is routed to a pixelspace 9. [K] API KSH command line does not work as expected due to not having an enable function in the command line 10. [K] PVW layers will show gap between stitched together layers, PGM does not show this and will transition properly on display 11. [K] 8 bit mode max canvas size is 73,360,128 pixels due to current firmware limitation 12. [K] 12 bit VI height max is 4316 13. [K] Layers could momentarily flicker when scaled all the way down to 0 14. [K] Direct AUX is not implemented yet - future release 15. [K] Outputs could take a long time to resync to display to show signal after shutdown and power up - can normally toggle connector to resync quicker 16. [K] Multiviewer preset doesn't update relearned Multiviewer presets after they have already been configured 17. [K] Multiviewer preset does not currently include Multiviewer template presets 18. [K] Cloning is not implemented yet - future release 19. [K] Factory output resolutions QXGA and 1366x768 don't currently send correct timing at 59.94hz 20. [K] Outputs could potentially flicker intermittently, mostly with custom resolutions 21. [K] Multiviewer is not currently supported with output resolution 4096x2160 22. [K] Applying a current configuration from the configuration manager will currently deprogram Multiviewer function key settings 23. [K] Read EDID from display device is not fully implemented yet and will create 0x0 EDID 24. [K] Still images don't currently clear on simulator and output when "clear all" is selected from building a new configuration 25. [K] Mix Thur Black mixer element on Multiviewer has a delayed transition in the PVW screen 26. [K] Layer doesn't freeze on output when it is in PVW 27. [-] Fixed Multiviewer overlays to remove when in configure source mode What's new in the Spyder Studio Client Version 0.100.18082.1457 (03-23-2018) =================================================================================================== Spyder FPGA Date: CP 20180116 IC 20180319 OC 20180320 IP 20180129 OP 20180131 =================================================================================================== Stability Index: 4 (Release Candidate) =================================================================================================== 1. [-] Fixed RRL command to report properly 2. [-] Fixed software from crashing when selecting the cancel button sometimes on output options 3. [-] Fixed RRC command to report properly 4. [-] Fixed software generated boarder and shadow (shape) from cutting off the lower portion of the layer What's new in the Spyder Studio Client Version 0.100.18081.1443 (03-23-2018) =================================================================================================== Spyder FPGA Date: CP 20180116 IC 20180319 OC 20180320 IP 20180129 OP 20180131 =================================================================================================== Stability Index: 3 (Beta) =================================================================================================== 1. [-] Fixed firewall error that caused some units to not allow the server to connect to the client 2. [-] Fixed Layers to use only 1 layer on height max 4096 instead of pulling 1 and 2 What's new in the Spyder Studio Client Version 0.100.18079.1507 (03-20-2018) =================================================================================================== Spyder FPGA Date: CP 20180116 IC 20180319 OC 20180320 IP 20180129 OP 20180131 =================================================================================================== Stability Index: 3 (Beta) =================================================================================================== 1. [+] Enhanced Multiviewer workflow 2. [-] Fix UI to remove router when selecting in the configuration manager 3. [-] Fixed UI to remove output on Multiviewer when output is changed to scaled or normal 4. [-] Fixed UI output settings to take changes 5. [-] Fixed tearing between and in outputs 6. [-] Fixed intermittent layer flicker 7. [-] Fixed Multiviewer cross point to properly switch inputs when switching between source view and op mon 8. [-] Fixed output frame lock indicator to properly track if the output is locked to the frame or not 9. [-] Fixed UI to not update scripting window when making a source change on random 10. [-] Fixed input boards from locking up 11. [+] Added right click in connection manager to go to webpage 12. [+] Added front panel dimming and message to wake when wanting to use 13. [K] Front panel firewall fault - could get some units stuck with flashing front panel red light and unable to connect 14. [K] Unplugging and plugging HDMI inputs could cause input to lockup and unable to sync until shutdown What's new in the Spyder Studio Client Version 0.100.18071.1029 (03-12-2018) =================================================================================================== Spyder FPGA Date: CP 20180116 IC 20180310 OC 20180125 IP 20180129 OP 20180131 =================================================================================================== Stability Index: 3 (Beta) =================================================================================================== 1. [-] Fixed MV name to update when input is router on the source mon label 2. [-] Fixed right click function to change command key type 3. [-] Fixed software from crashing when selecting a still image in the still list that isn't valid 4. [-] Stabilized frame lock on the outputs 5. [-] Fixed ALL PGM scaled view on outputs 6. [-] Fixed ALL PGM on the MV to work without being outside of the canvas 7. [-] Fixed entrance and exit control based on if it is enabled under server > frame configuration 8. [-] Fixed input configuration software bug with cut source disappearing 9. [-] Fixed SDI inputs from locking up when switching from different resolutions 10. [*] Implemented SDI interlaced input signal capability 11. [*] Improved still image loading into a layer 12. [+] Added function key to control "use backup" source 13. [+] Added new UI output properties view to match configuration manager 14. [K] Output properties don't update timings when refresh rate is changed 15. [K] SDI keying color is not working at full range. What's new in the Spyder Studio Client Version 0.100.18061.0646 (03-2-2018) =================================================================================================== Spyder FPGA Date: CP 20180116 IC 20180226 OC 20180125 IP 20180129 OP 20180131 =================================================================================================== Stability Index: 3 (Beta) =================================================================================================== 1. [-] Fixed inputs to turn to black when no signal is found 2. [-] Fixed Multiviewer presets to recall presets with labels 3. [-] Fixed custom resolution tab in the configuration manager 4. [-] Fixed Comm 1 and Comm 3 from being in the wrong order according to the labels 5. [-] Fixed Multiviewer PVW screen from disappearing sources when scaled larger than the pixelsapce 6. [-] Fixed MV preset from sourcemon to anything with PVW in it from freezing up 7. [*] Removed web UI restart, reboot, shutdown, and update functions for security purposes 8. [+] Added front panel genlock messages - Locked, unlocked, or off 9. [+] Added restriction to outputs dragging and dropping into a pixelspace to be scaled in output doesn't allow for it 10. [K] ALL PGM in MV is noise unless 32 pixels outside of the right MV boundary 11. [K] Large still images aren't scaling inside of layers and are grey/transparent unless previously used What's new in the Spyder Studio Client Version 0.100.18058.1148 (02-28-2018) =================================================================================================== Spyder FPGA Date: CP 20180116 IC 20180226 OC 20180125 IP 20180129 OP 20180131 =================================================================================================== Stability Index: 3 (Beta) =================================================================================================== 1. [-] updated IC firmware to improve display port input link training What's new in the Spyder Studio Client Version 0.100.18057.1135 (02-26-2018) =================================================================================================== Spyder FPGA Date: CP 20180116 IC 20180124 OC 20180125 IP 20180129 OP 20180131 =================================================================================================== Stability Index: 3 (Beta) =================================================================================================== 1. [-] Fixed input configuration raster arrows from distorting sources 2. [-] Fixed Multiviewer presets to switch individual pixel spaces without locking up 3. [-] Fixed Multiviewer labels to remove when applying a new configuration and clearing all data 4. [-] Fixed custom layout to save and not override changes 5. [-] Fixed genlock reporting on front panel 6. [-] Resolved multiple inconsistent configuration issues when applying a last used configuration 7. [-] Fixed spyder updater from breaking the server if a board does not update properly 8. [*] Changed the spyder UDP message Vista advanced can't see X80 hardware 9. [*] Added spyder studio documentation in the installer 10. [*] Added BT2020 color space to outputs 11. [*] Make startup function when startupcount file has unexpected values What's new in the Spyder Studio Client Version 0.100.18047.1311 (02-20-2018) =================================================================================================== Spyder FPGA Date: CP 20180116 IC 20180124 OC 20180125 IP 20180129 OP 20180131 =================================================================================================== Stability Index: 3 (Beta) =================================================================================================== 1. [-] Fixed T short cut transition key from PVW to PGM 2. [-] Fixed copy command key to keep command key color 3. [-] Fixed bleeding over pixelspace into first pixelspace on MV and scaled outputs 4. [-] Fixed hot sync lettering theme 5. [-] Fixed MV labels to remove when clearing a configuration and applying it to hardware 6. [-] Fixed empty layers to be transparent and not show blue/grey coloring 7. [-] Fixed cancel button in software while creating a new command key to not add it 8. [-] Fixed cropping layer while shadow is enable to persist without causing source noise 9. [-] Fixed adding large still images to scale down to UHD so they can show in a layer 10. [-] Fixed UHD rotation on outputs 11. [-] Fixed disconnect and pull option to save bit depth in the configuration What's new in the Spyder Studio Client Version 0.100.18040.1344 (02-9-2018) =================================================================================================== Spyder FPGA Date: CP 20180116 IC 20180124 OC 20180125 IP 20180129 OP 20180131 =================================================================================================== Stability Index: 3 (Beta) =================================================================================================== 1. [-] Fixed clicking sources tab inconsistencies 2. [-] Fixed thumbnail enlargement on the properties panel 3. [-] Improved configure source when whole canvas size is being used 4. [-] Fixed SDI output colorspace from needed to be manually adjusted 5. [-] Changed front panel window in the software to open independently to configure command keys, function keys, and test patterns 6. [-] Fixed boarders and shadows to work when whole canvas size is 1080p or higher 7. [-] Fixed right clicking on a relative command key to switch to absolute 8. [-] Fixed software from crashing when copying a command key using CTRL + Left click and drag drop 9. [-] Fixed output rotation 10. [-] Fixed deleting command keys to delete when chosen 11. [K] T and C transition not working when no layer is in PGM 12. [*] Changed properties panel tabs to remain all open unless user closes them manually 13. [+] Added input factory formats for UHD and 2160p What's new in the Spyder Studio Client Version 0.100.18033.1258 (02-5-2018) =================================================================================================== Spyder FPGA Date: CP 20180116 IC 20180124 OC 20180125 IP 20180129 OP 20180131 =================================================================================================== Stability Index: 3 (Beta) =================================================================================================== 1. [-] Fixed 8bit port C and D output UHD flicker 2. [-] Fixed configure source when whole canvas is being used. 3. [-] Fixed layer cropping 4. [-] Fixed configuration manager output resolution selection to update changes 5. [K] Right click and PVW source configuration is not working What's new in the Spyder Studio Client Version 0.100.18032.1434 (02-2-2018) =================================================================================================== Spyder FPGA Date: CP 20180116 IC 20180124 OC 20180125 IP 20180129 OP 20180131 =================================================================================================== Stability Index: 2 (Alpha) =================================================================================================== 1. [-] Fixed UHD HDMI 30hz output tearing 2. [-] Fixed "clear all data" in configuration to not clear router patch in the config. 3. [-] Fixed blended outputs test pattern from going dark 4. [-] Improved output rotation function on UHD and 1080p 5. [-] Fixed configuration manager to show all the resolutions per connector type in the list 6. [-] Improved front panel "Christie" splash screen to not hide the update progress during an update 7. [+] Added Multiselect treatments 8. [+] Added wait time feature on front panel to ensure all boards are ready for start up 9. [+] Added Multiselect function keys 10. [+] Added UHD and 4k 25hz/50hz to factory default list 11. [K] Front panel update screen improvements continue to be implemented 12. [K] Unmanaged switch static IP address inconsistencies. What's new in the Spyder Studio Client Version 0.100.18026.1452 (01-26-2018) =================================================================================================== Spyder FPGA Date: CP 20180116 IC 20180124 OC 20180117 IP 20180109 OP 20180124 =================================================================================================== Stability Index: 2 (Alpha) =================================================================================================== 1. [-] Fixed Canvas wider than 16384 distorts the scaled output and PGM in Multiviewer 2. [-] Fixed HDMI inputs from losing the input configuration 3. [-] Fixed HDMI inputs from locking up on startup 4. [-] Fixed scaled outputs on 1080p output resolution 5. [-] Fixed "mix background" duration function key 6. [-] Fixed display port EDID saving after shutdown 7. [-] Fixed PVW software active indicator to show regardless of PGM active or not 8. [-] Fixed router switching with same layer active 9. [-] Removed router from drop down list in desktop client after removing it in configuration manager 10. [-] Fixed configuration crashing from changing connector type on an output 11. [+] Update firmware on startup every time it is needed 12. [+] Implemented 8 bit mode 13. [*] Improved SDI output settings to change color space default to BT709 14. [K] Canvas height greater than 4320 flickers UHD outputs on port C and D 15. [K] Still working on full 80 million pixel 8 bit capability What's new in the Spyder Studio Client Version 0.100.18024.1416 (01-24-2018) =================================================================================================== Spyder FPGA Date: CP 20180116 IC 20180123 OC 20180117 IP 20180109 OP 20180123 =================================================================================================== Stability Index: 2 (Alpha) =================================================================================================== 1. [-] Upstream router switching speed 2. [-] Fixed HDMI input locking up on resolution change 3. [-] Fixed first input name on Multiviewer to show instead of N/A 4. [-] Fixed PVW indicator without PGM active 5. [-] Fixed tab key between properties functions 6. [-] Fixed display port EDID handling - now doesn't require hot plug 7. [-] Fixed router patch persisting after updating software 8. [-] Improved output rotation 9. [-] Fixed router properties saving after applying new configuration for serial port 10. [-] Fixed message for scaled output on ports C and D 11. [*] Improved refresh rate reporting on input signal 12. [K] PVW layers flash intermittently What's new in the Spyder Studio Client Version 0.100.18019.0714 (01-19-2018) =================================================================================================== Spyder FPGA Date: CP 20180116 IC 20171219 OC 2018117 IP 20180109 OP 20171214 =================================================================================================== Stability Index: 2 (Alpha) =================================================================================================== 1. [-] Fixed SDI output intermittent flickering 2. [-] Fixed router settings to persist across updates 3. [-] Fixed autosync function while source is in preview 4. [-] Fixed upstream router routing with drag and drop function 5. [-] Fixed Multiviewer layer offset on multiple pixelspaces 6. [-] Fixed backup configuration to save bit depth in file 7. [-] Fixed board size when scaling to follow scaling and not become larger or smaller 8. [-] Fixed re-learn Multiviewer function to save background colors 9. [*] Disconnects upstream router while in offline mode so not control or try to reach IP. 10. [*] Changed factory default to 12 bit mode 11. [*] Thumbnail capture improvements 12. [*] Enhance Multiviewer tool bars 13. [*] Disable direct aux until fully functioning 14. [*] Add message for scaled output on ports C and D What's new in the Spyder Studio Client Version 0.100.18015.1022 (01-15-2018) =================================================================================================== Spyder FPGA Date: CP 20171219 IC 20171219 OC 20171218 IP 20180109 OP 20171214 =================================================================================================== Stability Index: 2 (Alpha) =================================================================================================== 1. [-] Fixed "Select All" option for test patterns on front panel 2. [-] Fixed PVW mixer element from switching on PGM live cue 3. [-] Fixed fatal error when loading opmon without a preview 4. [-] Fixed shadows on layers to work in all directions and options 5. [-] Changing adjacent output connector type turns MV to noise 6. [-] Fixed Scaled output offset 7. [-] Fixed Unit reboots itself if loses IP address 8. [+] Auto sync unconfigured source to Multiviewer 9. [+] Change file format for X80 to .sproj 10. [+] Modify factory format for each connector type 11. [+] Support different firmware versions for different hardware revisions in auto update 12. [*] Filtered resolution list to populate depending on the connector type used 13. [*] Fixed properties panel function keys from missing functionality options 14. [*] Parallel system patch boundary fix for wide configurations 15. [*] Fixed Network so it doesn't go to 0.0.0.0 after update 16. [*] Router loses its configuration when new config is applied 17. [*] SDI 1080p inputs verified working and stable - known issue with 1080i inputs not stable. 18. [*] Firmware update robustness What's new in the Spyder Studio Client Version 0.018.09.14411 (01-10-2018) =================================================================================================== Spyder FPGA Date: CP 20171219 IC 20171219 OC 20171218 IP 20180109 OP 20171214 =================================================================================================== Stability Index: 2 (Alpha) =================================================================================================== 1. [+] Add firewall rule for server.exe on startup 2. [+] Remove X20 communication for spyder studio 3. [+] Add clear all test patterns to front panel 4. [+] Remove gateway requirement 5. [*] Adjust UI properties panel to align with panel 6. [*] Switched front panel command key ID to script ID 7. [*] Removed AOR boarder on show input and add new icon 8. [*] Fixed Sync files dialog box being cut off 9. [*] Disconnect and pull cuts off message box 10. [*] Fixed Function key save to file 11. [*] Re-added Load factory format ID 12. [-] Fixed Copy/Past that duplicated the paste twice 13. [-] Connecting to a local server and changing the alert viewer priority crashed the system 14. [-] Fixed Function key name change error 15. [-] Fixed general software functions for SDI outputs 16. [-] Multiviewer input mapping issue 17. [-] Fixed PGM/PVW labels that only worked one at a time 18. [-] Blocked the same input with a different connector from being applied while another is in use 19. [-] Fixed Treatments saving to file 20. [-] Show input not saving input number when applied 21. [-] Fixed restore configuration error 22. [-] Fixed backup configuration error 23. [-] Fixed Unit rebooting itself after several hours running a script 24. [-] Fixed Front Panel - test patterns do not work on certain sections 25. [-] Fixed Multiviewer pgm resizing inconsistency 26. [-] Fixed Multiviewer PVW inputs that won't change when a command key is recalled 27. [-] Fixed PVW background that doesn�t stay synchronized 28. [-] Fixed Sources that lose autosync on reboots What's new in the Spyder Studio Client Version 0.017.21.14360 (12-21-2017) =================================================================================================== Stability Index: 2 (Alpha) =================================================================================================== 1. [+] Add Edid version label in EDID manager 2. [+] Adding layers to PVW won't prevent adding layers to PGM 3. [+] Set cross point for Multiviewer port when setting preview layer sources 4. [+] Copy/Paste multiple command keys 5. [-] Fixed Simulator that can't load large size background images 6. [+] Show "edit canvas" wrap depending on size of config manager window 7. [*] Fixed Boarder/Shadows 8. [+] Change "read EDID from output" to "read EDID from display device" 9. [+] Improve desktop client connection manager 10. [-] Fixed EDID that can�t load from output 11. [+] Add option to choose bit depth in EDID manager 12. [*] Improved key frame issues in properties panel 13. [+] Front Panel - add functionality to have front panel buttons to wake up display that is asleep 14. [+] Set MV in hardware 15. [+] Add stills and shapes functionality in Multiviewer 16. [+] (backend) minimize Multiviewer config packet writes 17. [-] Fixed Multiviewer scaling PGM that distorts unless a multiple of 16 18. [*] Doing a factory reset doesn't create valid defaults and constantly reboots server 19. [+] Add Multiviewer labels What's new in the Spyder Studio Client Version 0.017.20.14343 (12-20-2017) =================================================================================================== Stability Index: 2 (Alpha) =================================================================================================== 1. [-] AMD display port capability 2. [-] 4 missing pixels on each output 3. [+] Copy/paste command keys 4. [-] Can�t load large size still images 5. [-] Input array doesn't show on PVW as expected 6. [*] Multiviewer isn't showing the correct configured pixelspace 7. [-] Offline sources are not showing in PVW space on a saved command key 8. [*] Property panels need adjustments in some areas 9. [*] Scripting window - source element doesn't update name 10. [-] No warning when still is trying to have a duplicate name 11. [*] Parallel configuration don't create as expected in simulator window 12. [*] Output pixelspace titling 13. [+] Front Panel - color test button 14. [+] Front Panel - report back duplicate IP address 15. [+] Front Panel - Restore factory defaults 16. [-] Artifacts show on source when moving in a script 17. [+] Multiviewer (hardware incorporated) 18. [*] Setting static IP address 19. [K] SDI output intermittently drops out 20. [K] Output rotation inconsistency What's new in the Spyder Studio Client Version 0.017.27.14218 (11-27-2017) =================================================================================================== Stability Index: 1 (Alpha) =================================================================================================== 1. [+] Output bit depth 8, 10, 12 2. [+] Image clean up when applying new config 3. [*] Configure chroma and colorspace output configuration 4. [*] Configure input chroma and color space 5. [*] (backend) configure output converter clock cleaner for any given output setting 6. [*] (backend) configure vsync and vfrontporch with bits shifted one left for non-interlaced digital cases 7. [*] All outputs default to 422 causing outputs to not work until changed to 444 and connector type toggled 8. [*] Canvas size doesn�t automatically reset when changed to 8bit from 12 bit 9. [*] Changing the still name will remove its thumbnail and the still from the properties window 10. [*] Custom format does not create correctly in configuration manager after applying - gave 0 values for all outputs 11. [*] Custom settings do not apply correctly to hardware - have to go to VESA timing after to choose "reduced blanking" and reapply it 12. [*] File > New changing to SDI connector factory format list shows no formats 13. [*] General options in output needs input number associated with "show input" 14. [*] Server > frame configuration - global settings don't save after applying its settings and restarting 15. [K] Blending goes dark when loading a test pattern to pixelspace 16. [*] Inside soft doesn't work unless outside soft boxes are deselected 17. [*] IP address does not show up in the server every time updating new software - reboot required 18. [+] Color change in some output properties to match new theme 19. [*] All properties panels consistently open the first tab each time 20. [*] View stack not laying out as expected 21. [*] Setting a background image to the simulator doesn�t load it to the outputs until the background is mixed 22. [*] Show input doesn�t change the input selected until the connector type is toggled 23. [*] Software will crash with fatal error when running idle for too long 24. [*] System Layout\< source Layer>\Properties\Input Configuration - change the Name field does not work 25. [*] System stuck in apply new configuration 26. [+] remove line associated with MV and pixelspace in system patch 27. [*] Online EDID manager won't create an EDID from factory DP 28. [*] Online EDID manager don't show in the list 29. [*] Online function key does not recall the MV preset 30. [+] Multi-command key recall 31. [*] Outside soft check boxes are inverted 32. [K] 8 bit configuration do not work 33. [*] Custom shape causes warning 34. [*] Frame rate not saving to EDID manager 35. [+] Front panel - command keys 36. [+] Front panel - function keys 37. [+] Front panel - load test patterns 38. [+] Global settings persist across updates 39. [*] Tearing across outputs 40. [+] (backend) increase pre-allocated DMA memory size to prevent problems on startup 41. [+] Make Chroma, bit depth, and TX mode accessible in general output options 42. [+] Make 12 bit default in the configuration manager 43. [+] Add multiple default factory EDID's 44. [+] New configuration should set last output or Multiviewer to "configuration output" 45. [+] Save user library�s 46. [K] Cloning not implemented yet 47. [*] Applying an EDID to input doesn't save 48. [*] Front panel doesn't show up when a monitor is plugged in 49. [+] (backend) set input chroma and colorspace in hardware 50. [+] (backend) set output chroma and colorspace in hardware 51. [+] Support front panel in imaging 52. [K] Empty layer shows color instead of being transparent 53. [K] UHD and 4k outputs tear at 30hz